model-number
HP-LASERJET-COMMON-MIB ·
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.1
Object
Identifies the device model number as listed in the HP corporate price list (e.g. C2121A for DeskJet 500C). The string is as specific as possible. Products should note in POS if the model number on the CPL changes but the device reports the previous model number. If the model number changes based on the installed options, the POS should indicate if only the base model number is returned, or if the device senses the installed options and returns the correct model number. If possible, encode the model number in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: The value of this object does not change based on the installed options.
Context
- MIB
- HP-LASERJET-COMMON-MIB
- OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.1- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- id
- Siblings
- 11
Values & Constraints
Enumerated Values
1 | eEmpty |
2 | eUnknown |
3 | eUnSupported |
4 | eReadOnlyMemory |
7 | eFlashMemory |
14 | eSDRandomAccessMemory |
15 | eSRandomAccessMemory |
16 | eFPMRandomAccessMemory |
17 | eEDORandomAccessMemory |
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| device-name mandatory User defined device name. The POS should indicate the
maximum supported string length. If the user entered
string is too long, the device will store as much as
possible and will… | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.10 |
| device-location mandatory User defined device location. The POS should indicate
the maximum supported string length. If the user
entered string is too long, the device will store as
much as possible and … | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.11 |
| asset-number mandatory User defined asset number. The POS should indicate the
maximum supported string length. If the user entered
string is too long, the device will store as much as
possible and wil… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.12 |
| system-contact mandatory User defined string containing the name of the person or
group that is responsible for the device. The POS
should indicate the maximum supported string length. If
the user enter… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.13 |
| fax-line-interface-unit-id mandatory The fax device line interface unit (LIU) identifier. The LIU
number identifies the telephone system electrical
characteristics supported by this device.
Additional information:
In… | scalar | Integer32 | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.18 |
| model-name mandatory Identifies the device model name (e.g. ''DeskJet 1200C''). The
string is as specific as possible. Capitalization and spacing
should match family naming conventions. Products shoul… | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.2 |
| serial-number mandatory Identifies the serial number for the device. If the
SERIAL-NUMBER object is set by the user, then setting
the object does not need to be protected. If the
SERIAL-NUMBER object i… | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.3 |
| fw-rom-datecode mandatory Identifies the base system firmware date code. The date
code will be encoded in the yyyymmdd format. There may
be several versions of the base system firmware. The
date code as… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.5 |
| fw-rom-revision mandatory This identifies the system code firmware ROM revision code. The
format for a revision is major_revision.minor_revision. There
may be other ROM revision code objects for other spec… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.6 |
| fax-local-phone-num mandatory CCITT sender's station id (ex. 08-396-4122). | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.8 |
| fax-station-name mandatory name for the fax device (ex. HP R&D). | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.9 |