Enumeration
A device can support a class of errors called continuable errors. When a continuable error is encountered, the device requires a continue event to occur before the device will continue operation. One continue event is setting the CONTINUE object to eInitiateAction. Devices can support other continue events, like auto-continue. A continue event causes the continuable error to be acknowledged, thus allowing the device to continue. Each device needs to list the continuable errors. If the device doesn't currently have an unacknowledged continuable error, the response will contain <genErr>. Additional information: See the CLEARABLE-WARNING and AUTO-CONTINUE objects for the errors that this object will clear.
Context
- MIB
- HP-LASERJET-COMMON-MIB
- OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.6- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- status-system
Syntax
Enumeration
Values & Constraints
Object Constraints
range: 0-16