auto-continue
HP-LASERJET-COMMON-MIB ·
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7
Object
scalar mandatory
r/w
Enumeration
Indicates if the device will automatically continue
after encountering a continuable error. If AUTO-
CONTINUE is set to eOn, the device will automatically
generate continue event to acknowledge continuable
errors. If AUTO-CONTINUE is set to eOff, then some
other continue event will have to acknowledge the
continuable error.
Additional information:
If this is set to eOn the device displays an
error message and goes offline for ten seconds. After ten seconds the
printer automatically returns to the online state.
If this is set to eOff then the device displays an error message and
goes offline. It remains offline until the operator presses the GO key or
until the CONTINUE object is set.
If the printer is not idle, the new value may not take effect
until a job boundary is reached. If a get is done on this object before
the job boundary is reached, the value last set will be returned.
Context
- MIB
- HP-LASERJET-COMMON-MIB
- OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- status-system
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HP-LASERJET-COMMON-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HP-LASERJET-COMMON-MIB::auto-continue.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HP-LASERJET-COMMON-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HP-LASERJET-COMMON-MIB::auto-continue'
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | eClearErrorLog |