hpicfMacNotifyTrapInterval

HP-ICF-MACNOTIFY-MIB · .1.3.6.1.4.1.11.2.14.11.5.1.66.1.2

Object

scalar r/w Seconds Unsigned32
Defines the interval in seconds between sending
hpicfMacNotifyMacAddressTableChange
notifications.  The notifications will be
buffered on the system until the interval.
If the buffer becomes full before the interval,
the full buffer will be sent. 
          
A value of 0 (zero) indicates MAC address
changes will be sent when the event occurs.
Default value is 30 seconds.

Context

MIB
HP-ICF-MACNOTIFY-MIB
OID
.1.3.6.1.4.1.11.2.14.11.5.1.66.1.2
Type
scalar
Access
readwrite
Status
current
Units
Seconds
Parent
hpicfMacNotifyConfigObjects

Syntax

Seconds Unsigned32

Values & Constraints