hpFtrCoEntityDate

HP-ICF-FTRCO · .1.3.6.1.4.1.11.2.14.11.5.1.46.1.1.1.3

Object

This represents the switch's understanding of the current UTC time.
It should be used when setting an restriction expiration 
DateAndTime value.  Please note that this value is uniquely 
determined each time the object is read (dynamic) and is 
subject to changing when a change is made to the switch's
configuration (e.g. setting the local time-zone).

Context

MIB
HP-ICF-FTRCO
OID
.1.3.6.1.4.1.11.2.14.11.5.1.46.1.1.1.3
Type
column
Access
readonly
Status
current
Parent
hpFtrCoEntityEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HP-ICF-FTRCO' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HP-ICF-FTRCO::hpFtrCoEntityDate'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HP-ICF-FTRCO' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HP-ICF-FTRCO::hpFtrCoEntityDate.<hpFtrCoEntityName>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HP-ICF-FTRCO' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HP-ICF-FTRCO::hpFtrCoEntityDate'

Syntax

Source
SNMPv2-TCDateAndTime
Base type
OctetString
Display format
2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Type Description
A date-time specification.
          
field  octets  contents                  range
-----  ------  --------                  -----
  1      1-2   year*                     0..65536
  2       3    month                     1..12
  3       4    day                       1..31
  4       5    hour                      0..23
  5       6    minutes                   0..59
  6       7    seconds                   0..60
               (use 60 for leap-second)
  7       8    deci-seconds              0..9
  8       9    direction from UTC        '+' / '-'
  9      10    hours from UTC*           0..13
 10      11    minutes from UTC          0..59
          
* Notes:
- the value of year is in network-byte order
- daylight saving time in New Zealand is +13
          
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
displayed as:
          
                 1992-5-26,13:30:15.0,-4:0
          
Note that if only local time is known, then timezone
information (fields 8-10) is not present.

Values & Constraints

Type Constraints
range: 8 range: 11

Conformance