hpRptrMonGlobalFCSErrors

HP-ICF-8023-RPTR · .1.3.6.1.4.1.11.2.14.11.2.2.1.1.3

Object

scalar deprecated SNMPv2-SMICounter32
********* THIS OBJECT IS DEPRECATED *********
          
This counter is incremented by one for each frame
received on any port with the FCSError signal
asserted and the FramingError and CollisionEvent
signals deasserted and whose OctetCount is greater
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 
Std).  This counter is the summation of the values
of the rptrMonitorPortFCSErrors counter for all of
the ports in this repeater.

Context

MIB
HP-ICF-8023-RPTR
OID
.1.3.6.1.4.1.11.2.14.11.2.2.1.1.3
Type
scalar
Access
readonly
Status
deprecated
Parent
hpRptrMonCounters
Groups
2

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HP-ICF-8023-RPTR' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HP-ICF-8023-RPTR::hpRptrMonGlobalFCSErrors.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HP-ICF-8023-RPTR' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HP-ICF-8023-RPTR::hpRptrMonGlobalFCSErrors'

Syntax

Source
SNMPv2-SMICounter32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295