prtinputcurrentlevel

HP-Color-LaserJet-4500-MIB · .1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.10

Object

scalar optional Integer32
The current capacity of the input sub-unit in input
sub-unit capacity units (PrtCapacityUnitTC). If this input
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by
management requests; otherwise, the value may
be written (by a Remote Contol Panel or a
Management Application).  The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter. The value (-2) means unknown.
The value (-3) means that the printer knows that at least one
unit remains.
        Additional information:
        LaserJet 4500 can only detect empty/not empty in it's
        trays. It returns -3 for not empty and 0 for empty.
        If a tray is removed, a value of -2 (unknown) will  
        be returned.  The tray 3 object does not exist when that option
        is NOT installed.

Context

MIB
HP-Color-LaserJet-4500-MIB
OID
.1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.10
Type
scalar
Access
readonly
Status
optional
Parent
prtInputEntry

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HP-Color-LaserJet-4500-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HP-Color-LaserJet-4500-MIB::prtinputcurrentlevel.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HP-Color-LaserJet-4500-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HP-Color-LaserJet-4500-MIB::prtinputcurrentlevel'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647