hzOduModem1ChannelizedRslBelowThresholdParameters
HORIZON-ODU-MIB ·
.1.3.6.1.4.1.7262.2.2.5.1.2.12
Object
A read-write string: The threshold in dBm and the number of seconds threshold are programmed by the user. An example of the format of the string is as follows: '-75 10'. The first parameter power level in dBm, the second is the time in seconds that the threshold must be exceeded. In this example the threshold -75 dBm and the time is set to 10 seconds. The single quote marks i.e. ' ' are not used in the command.
Context
- MIB
- HORIZON-ODU-MIB
- OID
.1.3.6.1.4.1.7262.2.2.5.1.2.12- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- hzOduModem1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HORIZON-ODU-MIB' -M '/opt/observium/mibs/dragonwave:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HORIZON-ODU-MIB::hzOduModem1ChannelizedRslBelowThresholdParameters.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HORIZON-ODU-MIB' -M '/opt/observium/mibs/dragonwave:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HORIZON-ODU-MIB::hzOduModem1ChannelizedRslBelowThresholdParameters'
Syntax
- Source
- DisplayString
- Base type
OctetString
Values & Constraints
Object Constraints
range: 0-24