hm2Iec62541OpcUaMaxSessionsCount

HM2-INDUSTRIAL-PROTOCOLS-MIB · .1.3.6.1.4.1.248.11.101.1.5.1.3

Object

scalar r/w Integer32
Maximum number of OpcUa sessions.
An integer value from 1 to 5 specifies
the maximum number of OpcUa sessions that can be established.
The full range is not supported by all variants.

Context

MIB
HM2-INDUSTRIAL-PROTOCOLS-MIB
OID
.1.3.6.1.4.1.248.11.101.1.5.1.3
Type
scalar
Access
readwrite
Status
current
Parent
hm2Iec62541ConfigGroup

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HM2-INDUSTRIAL-PROTOCOLS-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2Iec62541OpcUaMaxSessionsCount.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HM2-INDUSTRIAL-PROTOCOLS-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2Iec62541OpcUaMaxSessionsCount'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-5