hm2Iec61850MmsServerTechnicalKey

HM2-INDUSTRIAL-PROTOCOLS-MIB · .1.3.6.1.4.1.248.11.101.1.1.1.5

Object

scalar r/w OctetString
The IEC61850 MMS server technical key setting corresponds to the IEC61850 IED name. 
This name is used to identify the device via a IEC61850 MMS client. 
The size is restricted to 32 characters. According to IEC61850-7-2 Ed. the TechnicalKey represents
an IEC61850 VisibleString. Thus the following characters are allowed:
VisibleString ( FROM
	('A'|'a'|'B'|'b'|'C'|'c'|'D'|'d'|'E'|'e'|'F'|'f'|
	'G'|'g'|'H'|'h'|'I'|'i'|'J'|'j'|'K'|'k'|'L'|'l'|
	'M'|'m'|'N'|'n'|'O'|'o'|'P'|'p'|'Q'|'q'|'R'|'r'|
	'S'|'s'|'T'|'t'|'U'|'u'|'V'|'v'|'W'|'w'|'X'|'x'|
	'Y'|'y'|'Z'|'z'|'_'|'0'|'1'|'2'|'3'|'4'|'5'|'6'|
	'7'|'8'|'9') )

Context

MIB
HM2-INDUSTRIAL-PROTOCOLS-MIB
OID
.1.3.6.1.4.1.248.11.101.1.1.1.5
Type
scalar
Access
readwrite
Status
current
Parent
hm2Iec61850ConfigGroup
Siblings
15

Syntax

OctetString

Values & Constraints

Object Constraints
range: 0-32

Related Objects