hh3cSysClockProtocol
HH3C-SYS-MAN-MIB ·
.1.3.6.1.4.1.25506.2.3.1.1.4.1
Object
scalar
r/w
Enumeration
Writing none(1) to this object indicates to use the local system time.
When the value is set to none(1), hh3cSysClockProtocolSrcMdc and
hh3cSysClockProtocolSrcContext cannot be written and the value will be
set to invalid. Change system time will be performed through the node
of hh3cSysLocalClock and hh3cSysSummerTime.
Writing ntp(2) to this object indicates to use NTP time source.
NTP means Network Time Protocol. To get the system time through NTP,
NTP must be configured successfully. NTP time source can be obtained
from non-default MDC and non-default context.
When ntp(2) is set, the system time can't be changed manually.
Support for this keyword depends on the device model.
Writing ptp(3) to this object indicates to use PTP time source.
PTP means Precision Time Protocol. To get clock time through PTP, PTP
must be configured successfully. PTP time source can be obtained from
non-default MDC but cannot be obtained from non-default context.
When ptp(3) is set, the system time can't be changed manually.
Support for this keyword depends on the device model.
Writing interface(4) to this object indicates to get time source from interface.
To get clock time through interface, interface must be configured successfully.
When interface(4) is set, the system time can't be changed manually.
Support for this keyword depends on the device model.
Writing gnss(5) to this object indicates to get time source from Global
Natvigtion Satelite System(GNSS).GNSS time source can be obtained from
non-default MDC and non-default context. When gnss(5) is set, the system time
can't be changed manually.
Support for this keyword depends on the device model.
All MDCs on the device share the same time source and use the same system time.
The shared time source can be one of the following items:
Local system time - the time signal that is generated by the local
crystal oscillator
Remote time source - the time signal that is obtained by the specified MDC
from another device on the network.
Context
- MIB
- HH3C-SYS-MAN-MIB
- OID
.1.3.6.1.4.1.25506.2.3.1.1.4.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hh3cSysClockProtocolGroup
- Siblings
- 2
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | none |
2 | ntp |
3 | ptp |
4 | interface |
5 | gnss |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hh3cSysClockProtocolSrcMdc The MDC ID that is used for the system time source.
This node is valid when the clock protocol is NTP or PTP.
If MDC is not supported on this system, this node is invalid.
If the … | scalar | Integer32 | .1.3.6.1.4.1.25506.2.3.1.1.4.2 |