chargeFaultDaily

GENSTAR · .1.3.6.1.4.1.33333.10.54

Object

CHARGE_FAULT_DAILY
- Description: Charge fault daily bitfield
- Modbus address: 0x0226

Context

MIB
GENSTAR
OID
.1.3.6.1.4.1.33333.10.54
Type
scalar
Access
readonly
Status
current
Parent
genStar

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'GENSTAR' -M '/opt/observium/mibs/morningstar:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'GENSTAR::chargeFaultDaily.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'GENSTAR' -M '/opt/observium/mibs/morningstar:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'GENSTAR::chargeFaultDaily'

Syntax

Source
ChargeFaultBitfield
Base type
Bits
Type Description
Charge fault bitfield

Values & Constraints

Type Values
0charge-software
1charge-batt-hvd
2charge-rts-short
3charge-rts-disc
4charge-slave-to