sensorGroupConfigRunScriptDelta
G6-SMARTOFFICE-MIB ·
.1.3.6.1.4.1.3181.10.6.4.99.5.1.7
Object
Defines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent value is expected.
Context
- MIB
- G6-SMARTOFFICE-MIB
- OID
.1.3.6.1.4.1.3181.10.6.4.99.5.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- sensorGroupConfigEntry
- Table
- sensorGroupConfigTable
- Siblings
- 16
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sensorGroupConfigIndex Automatically generated | column | Integer32 | .1.3.6.1.4.1.3181.10.6.4.99.5.1.1 |
| sensorGroupConfigReportMode Defines if the sensor is passive or actively reports changes and error conditions | column | Enumeration | .1.3.6.1.4.1.3181.10.6.4.99.5.1.10 |
| sensorGroupConfigAdditionalParameter Comma separated list of any parameter specific for this attribute if needed. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.11 |
| sensorGroupConfigLowerBoundary When the measured value of any sensor is equal or below this value an event is raised. The value may be configured directly with a numerical value optionally followed by a unit. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.12 |
| sensorGroupConfigUpperBoundary When the measured value of any sensor is equal or above this value an event is raised. The value may be configured directly with a numerical value optionally followed by a unit. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.13 |
| sensorGroupConfigBoundaryHysteresis How much the value must return within bounds before the alarm condition is cleared. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.4.99.5.1.14 |
| sensorGroupConfigUpdateDelta Defines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent value is expected. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.15 |
| sensorGroupConfigRateLimit Defines how quickly the value is reported. Defined In units of 100ms. 0 means no rate limiting. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.3181.10.6.4.99.5.1.16 |
| sensorGroupConfigClearValues Clear status values for minimum_peak_hold and maximum_peak_hold. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.17 |
| sensorGroupConfigGroupName Unique group name referenced by the director | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.2 |
| sensorGroupConfigAttribute The attribute which is configured. Locally, identical attributes of the associated devices listed below are grouped. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.3 |
| sensorGroupConfigAssociatedDevices List of all sensors that supply information to a particular group. When an instance is used, here the syntax devicename.instance is used. All records are comma separated. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.4 |
| sensorGroupConfigValueCaching When enabled the group target value is saved to local non volaive memory. Should the director restart, the cached values will be restored and send to the devices. This feature is … | column | Enumeration | .1.3.6.1.4.1.3181.10.6.4.99.5.1.5 |
| sensorGroupConfigRunScriptWhen Defines which sensor group status needs to change in order to run the standard (and optional additional_script). This can be used to limit the number of script runs by not followi… | column | Enumeration | .1.3.6.1.4.1.3181.10.6.4.99.5.1.6 |
| sensorGroupConfigScriptName When the group is updated and the required conditions are met, the script specified in this parameter is executed. If the parameter is left blank, the standard MS_SmartOfficeContr… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.8 |
| sensorGroupConfigAdditionalScriptName When the group is updated and the required conditions are met and a script is defined here, this script is executed in the background after the standard processing for this group … | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3181.10.6.4.99.5.1.9 |