auto-continue

FUTURESMART-MIB · .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7

Object

scalar optional r/w Enumeration
Indicates if the device will automatically continue after
encountering a continuable error. If AUTO-CONTINUE is set to
eOn, the device will automatically generate continue event to
acknowledge continuable errors. If AUTO-CONTINUE is set to
eOff, then some other continue event will have to acknowledge
the continuable error.Interaction May not be settable if NOT-IDLE contains the cProcessingPDL
item. See continue object for a   description  of continuable errors

Context

MIB
FUTURESMART-MIB
OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7
Type
scalar
Access
readwrite
Status
optional
Parent
status-system

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'FUTURESMART-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FUTURESMART-MIB::auto-continue.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'FUTURESMART-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'FUTURESMART-MIB::auto-continue'

Syntax

Enumeration

Values & Constraints

Enumerated Values
1eOff
2eOn