fsUrpfDropNotifyHoldDownTime

FS-URPF-MIB · .1.3.6.1.4.1.52642.1.1.10.2.46.0.1.3

Object

scalar r/w seconds Integer32
The minimum time between issuance of 
fsUrpfIfDropRateNotify notifications for a 
particular interface and packet forwarding type.
          
Notifications are generated for each interface and
packet forwarding type that exceeds the drop-rate. 
When a Notify is sent because the drop-rate is 
exceeded for a particular interface and forwarding
type, the time specified by this object is used to 
specify the minimum time that must elapse before 
another Notify can be sent for that interface and
forwarding type. The time is specified globally but 
used individually.
          
Relation CLI: ip verify urpf drop-rate notify hold-down seconds.

Context

MIB
FS-URPF-MIB
OID
.1.3.6.1.4.1.52642.1.1.10.2.46.0.1.3
Type
scalar
Access
readwrite
Status
current
Units
seconds
Parent
fsUrpfScalar
Siblings
2

Syntax

seconds Integer32

Values & Constraints

Object Constraints
range: 30-300

Related Objects

Sibling Objects