frsldPvcCtrlLastPurgeTime
FRSLD-MIB ·
.1.3.6.1.2.1.95.1.1.1.11
Object
column
SNMPv2-TCTimeStamp
This object returns the value of sysUpTime
at the time the information was last purged.
This value SHOULD be set to the sysUpTime
upon setting frsldPvcCtrlStatus to active(1)
for the first time. Each time a
discontinuity in the counters occurs, this
value MUST be set to the sysUpTime.
If frsldPvcCtrlStatus has never been active(1),
this object SHOULD return 0.
This object SHOULD be used as the discontinuity
timer for the counters in frsldPvcDataTable.
Context
- MIB
- FRSLD-MIB
- OID
.1.3.6.1.2.1.95.1.1.1.11- Type
- column
- Access
- readonly
- Status
- current
- Parent
- frsldPvcCtrlEntry
- Table
- frsldPvcCtrlTable
- Siblings
- 10
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| frsldPvcCtrlDlci The value of this object is equal to the DLCI
value for this PVC. | column | FRAME-RELAY-DTE-MIBDLCI | .1.3.6.1.2.1.95.1.1.1.1 |
| frsldPvcCtrlDeleteOnPurge This object defines whether rows will
automatically be deleted from the tables
when the information is purged.
- A value of none(1) indicates that no rows
will de… | column | Enumeration | .1.3.6.1.2.1.95.1.1.1.10 |
| frsldPvcCtrlTransmitRP The reference point this PVC uses for calculation
of transmitter related statistics. This object
together with frsldPvcCtrlReceiveRP define the
measurement domain. | column | FrsldTxRP | .1.3.6.1.2.1.95.1.1.1.2 |
| frsldPvcCtrlReceiveRP The reference point this PVC uses for calculation
of receiver related statistics. This object
together with frsldPvcCtrlTransmitRP define the
measurement domain. | column | FrsldRxRP | .1.3.6.1.2.1.95.1.1.1.3 |
| frsldPvcCtrlStatus The status of the current row. This object is
used to add, delete, and disable rows in this
table. When the status changes to active(1) for the
first time, a row will also be ad… | column | SNMPv2-TCRowStatus | .1.3.6.1.2.1.95.1.1.1.4 |
| frsldPvcCtrlPacketFreq The frequency in seconds between initiation of
specialized packets used to collect delay and / or
delivery information as supported by the device.
A value of zero indicates that n… | column | seconds Integer32 | .1.3.6.1.2.1.95.1.1.1.5 |
| frsldPvcCtrlDelayFrSize The size of the payload in the frame used for
calculation of network delay. | column | octets Integer32 | .1.3.6.1.2.1.95.1.1.1.6 |
| frsldPvcCtrlDelayType The type of delay measurement performed. | column | Enumeration | .1.3.6.1.2.1.95.1.1.1.7 |
| frsldPvcCtrlDelayTimeOut A delay frame will count as a missed poll if
it is not updated in the time specified by
frsldPvcCtrlDelayTimeOut. | column | seconds Integer32 | .1.3.6.1.2.1.95.1.1.1.8 |
| frsldPvcCtrlPurge This object defines the amount of time the device
will wait, after discovering that a DLCI does not exist,
the DLCI was deleted or the value of frsldPvcCtrlStatus
changes from act… | column | seconds Integer32 | .1.3.6.1.2.1.95.1.1.1.9 |