snChasUnitPartNum
FOUNDRY-SN-AGENT-MIB ·
.1.3.6.1.4.1.1991.1.1.1.4.1.1.7
Object
column
DisplayString
The part number of the chassis for each unit. If the part number is unknown or unavailable then the value should be a zero length string.
Context
- MIB
- FOUNDRY-SN-AGENT-MIB
- OID
.1.3.6.1.4.1.1991.1.1.1.4.1.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- snChasUnitEntry
- Table
- snChasUnitTable
- Siblings
- 8
Syntax
DisplayString
- Source
- DisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| snChasUnitIndex The index to chassis table. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.1.4.1.1.1 |
| snChasUnitSerNum The serial number of the chassis for each unit. If the
serial number is unknown or unavailable then
the value should be a zero length string. | column | OctetString | .1.3.6.1.4.1.1991.1.1.1.4.1.1.2 |
| snChasUnitNumSlots Number of slots of the chassis for each unit. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.1.4.1.1.3 |
| snChasUnitActualTemperature Temperature of the chassis. Each unit is 0.5 degrees Celcius.
Only management module built with temperature sensor hardware
is applicable. For those non-applicable management modu… | column | Integer32 | .1.3.6.1.4.1.1991.1.1.1.4.1.1.4 |
| snChasUnitWarningTemperature Actual temperature higher than this threshold value will trigger
the switch to send a temperature warning trap. Each unit is 0.5
degrees Celcius. Only management module built with… | column | Integer32 | .1.3.6.1.4.1.1991.1.1.1.4.1.1.5 |
| snChasUnitShutdownTemperature Actual temperature higher than this threshold value will shutdown
a partial of the switch hardware to cool down the system. Each unit
is 0.5 degrees Celcius. Only management modul… | column | Integer32 | .1.3.6.1.4.1.1991.1.1.1.4.1.1.6 |
| snChasUnitIgnoreShutdownTemperature Enable/Disable the temperature threshold shutdown (Battleshort mode) feature on the unit specific.
Able to fetch the temperature threshold shutdown (Battleshort mode) feature stat… | column | Enumeration | .1.3.6.1.4.1.1991.1.1.1.4.1.1.8 |
| snChasUnitFanless Fanless mode can be enabled or disabled on certain FI devices.
none (0): not applicable to the device.
enabled(1): fanless mode is enabled on the device
disabled(2): fanless mode … | column | Enumeration | .1.3.6.1.4.1.1991.1.1.1.4.1.1.9 |