flWorkFWCtrlWatchdog
FL-MGD-INFRASTRUCT-MIB ·
.1.3.6.1.4.1.4346.11.11.11.2.1.3
Object
scalar
r/w
Enumeration
Setting this object to enable(2) activates the
watchdog during the next restart.
This Watchdog monitors the reliable operation
of the device. If the reliable operation cannot
be ensured any longer, then the outputs of the
modules are brought into the safe operating condition.
When this object is enabled then the switch is
automatically restarted else, when disabled, should be
manually restarted.
The modified adjustments become effective after
a restart of the device.
Context
- MIB
- FL-MGD-INFRASTRUCT-MIB
- OID
.1.3.6.1.4.1.4346.11.11.11.2.1.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- flWorkFWCtrlBasic
Syntax
Enumeration
Values & Constraints