f3TwampSessionSenderStartTime
F3-TWAMP-MIB ·
.1.3.6.1.4.1.2544.1.12.33.1.8.1.17
Object
column
r/w
OctetString
This is the time part of the Session Sender start time. When TWAMP Control
is enabled, the Date and Time are converted to the NTP timestamp format as
defined in RFC 1305 [REF13] to send in Request-TW-Session message.
The first 32 bits are the seconds since 0h Jan 1 1900 and the second 32 bits
is the fractional second and is the number of units of 200 picoseconds.
If f3TwampSessionSenderStartTimeType is IMMEDIATE, this attribute is not applicable.
If f3TwampSessionSenderStartTimeType is RELATIVE, this attribute is not applicable.
If f3TwampSessionSenderStartTimeType is FIXED, this attribute is the time
when to start the test.
Context
- MIB
- F3-TWAMP-MIB
- OID
.1.3.6.1.4.1.2544.1.12.33.1.8.1.17- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- f3TwampSessionSenderEntry
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-0
range: 8-8