f3SyncJScheduleGroupStartTime
F3-SYNCJACK-MIB ·
.1.3.6.1.4.1.2544.1.12.22.1.10.1.5
Object
This object allows specification of the start time of the SyncJack Schedule Group. Value of time less than current system time will equate to current time. When the system time reaches this configured time, the SyncJack Schedule Group will be activated.
Context
- MIB
- F3-SYNCJACK-MIB
- OID
.1.3.6.1.4.1.2544.1.12.22.1.10.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- f3SyncJScheduleGroupEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F3-SYNCJACK-MIB' -M '/opt/observium/mibs/adva:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F3-SYNCJACK-MIB::f3SyncJScheduleGroupStartTime'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'F3-SYNCJACK-MIB' -M '/opt/observium/mibs/adva:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F3-SYNCJACK-MIB::f3SyncJScheduleGroupStartTime.<neIndex>.<shelfIndex>.<slotIndex>.<f3SyncJScheduleGroupIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'F3-SYNCJACK-MIB' -M '/opt/observium/mibs/adva:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'F3-SYNCJACK-MIB::f3SyncJScheduleGroupStartTime'
Syntax
- Source
- SNMPv2-TCDateAndTime
- Base type
OctetString- Display format
2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Type Description
A date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes:
- the value of year is in network-byte order
- daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone
information (fields 8-10) is not present.
Values & Constraints
Type Constraints
range: 8
range: 11
Conformance
Member of