agentPortLoadStatsInterval

EdgeSwitch-SWITCHING-MIB · .1.3.6.1.4.1.4413.1.1.1.2.13.1.40

Object

column r/w Integer32
The length of time for which data is used to compute load statistics.
The value is given in seconds, and must be a multiple of 30.  The allowable
range is 30 to 600 seconds.

Context

MIB
EdgeSwitch-SWITCHING-MIB
OID
.1.3.6.1.4.1.4413.1.1.1.2.13.1.40
Type
column
Access
readwrite
Status
current
Parent
agentPortConfigEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EdgeSwitch-SWITCHING-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EdgeSwitch-SWITCHING-MIB::agentPortLoadStatsInterval'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EdgeSwitch-SWITCHING-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EdgeSwitch-SWITCHING-MIB::agentPortLoadStatsInterval.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EdgeSwitch-SWITCHING-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EdgeSwitch-SWITCHING-MIB::agentPortLoadStatsInterval'

Syntax

Integer32

Values & Constraints

No enumerated values or constraints recorded.