extremeSystemPowerMonitorPollInterval
EXTREME-SYSTEM-MIB ·
.1.3.6.1.4.1.1916.1.1.1.41.1.2
Object
column
r/w
Integer32
Configure how often input power is measured. it is configured in seconds. default value is 60 seconds. if 0 is configured then the input power measurement is disabled
Context
- MIB
- EXTREME-SYSTEM-MIB
- OID
.1.3.6.1.4.1.1916.1.1.1.41.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- extremeSystemPowerMonitorEntry
- Table
- extremeSystemPowerMonitorTable
- Siblings
- 3
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-300
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| extremeSystemPowerMonitorIndex1 Reserved can be used for future expansion. currently set to zero. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1916.1.1.1.41.1.1 |
| extremeSystemPowerMonitorReportChanges configure report-changes has none or log or trap or log-and-trap, by default none is configured | column | Enumeration | .1.3.6.1.4.1.1916.1.1.1.41.1.3 |
| extremeSystemPowerMonitorChangeThreshold configure input power change-threshold to initiate report-changes action.
By default 2 watts is configured, this field is configured in watts. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1916.1.1.1.41.1.4 |