extremePowerSupplyOutputUnitMultiplier
EXTREME-SYSTEM-MIB ·
.1.3.6.1.4.1.1916.1.1.1.38.1.5
Object
column
UnitMultiplier
The magnitude of volts and amps for the usage value in extremePowerSupplyOutputVoltage and extremePowerSupplyOutputCurrent.
Context
- MIB
- EXTREME-SYSTEM-MIB
- OID
.1.3.6.1.4.1.1916.1.1.1.38.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- extremePowerSupplyOutputPowerEntry
- Table
- extremePowerSupplyOutputPowerTable
- Siblings
- 4
Syntax
UnitMultiplier
- Source
- UnitMultiplier
- Base type
Enumeration
Values & Constraints
Type Values
-24 | yocto |
-21 | zepto |
-18 | atto |
-15 | femto |
-12 | pico |
-9 | nano |
-6 | micro |
-3 | milli |
0 | units |
3 | kilo |
6 | mega |
9 | giga |
12 | tera |
15 | peta |
18 | exa |
21 | zetta |
24 | yotta |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| extremePowerSupplyIndex Power supply unit slot index | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1916.1.1.1.38.1.1 |
| extremePowerSupplyOutputSensorIdx Power supply Sensor Index | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1916.1.1.1.38.1.2 |
| extremePowerSupplyOutputVoltage Output voltage per sensor for the current psu slot no.
0 in this field tells the psu doesnt support output voltage reading or output voltage read error. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1916.1.1.1.38.1.3 |
| extremePowerSupplyOutputCurrent Output current per sensor for the current psu slot no.
0 in this field tells the psu doesnt support output current reading or output current read error. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1916.1.1.1.38.1.4 |