entPhysicalSerialNum
OBS ✓
ENTITY-MIB ·
.1.3.6.1.2.1.47.1.1.1.1.11
Object
column r/w
OctetString
The vendor-specific serial number string for the physical
entity. The preferred value is the serial number string
actually printed on the component itself (if present).
On the first instantiation of a physical entity, the value
of entPhysicalSerialNum associated with that entity is set
to the correct vendor-assigned serial number, if this
information is available to the agent. If a serial number
is unknown or non-existent, the entPhysicalSerialNum will be
set to a zero-length string instead.
Note that implementations that can correctly identify the
serial numbers of all installed physical entities do not
need to provide write access to the entPhysicalSerialNum
object. Agents that cannot provide non-volatile storage
for the entPhysicalSerialNum strings are not required to
implement write access for this object.
Not every physical component will have a serial number, or
even need one. Physical entities for which the associated
value of the entPhysicalIsFRU object is equal to 'false(2)'
(e.g., the repeater ports within a repeater module) do not
need their own unique serial numbers. An agent does not
have to provide write access for such entities and may
return a zero-length string.
If write access is implemented for an instance of
entPhysicalSerialNum and a value is written into the
instance, the agent must retain the supplied value in the
entPhysicalSerialNum instance (associated with the same
physical entity) for as long as that entity remains
instantiated. This includes instantiations across all
re-initializations/reboots of the network management system,
including those resulting in a change of the physical
entity's entPhysicalIndex value.
Observium directly uses this object
This object is referenced by an Observium discovery or polling workflow.
Used in:
Inventory
Polling
Explore Observium network monitoring
Context
- MIB
- ENTITY-MIB
- OID
.1.3.6.1.2.1.47.1.1.1.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- entPhysicalEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ENTITY-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENTITY-MIB::entPhysicalSerialNum'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ENTITY-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENTITY-MIB::entPhysicalSerialNum.<entPhysicalIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ENTITY-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ENTITY-MIB::entPhysicalSerialNum'
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-32
Conformance
Member of
Compliance refinements
Read and write access is not required for agents that
cannot identify serial number information for physical
entities, and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for
physical entities for which the associated value of the
entPhysicalIsFRU object is equal to 'false(2)'.
cannot identify serial number information for physical
entities, and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for
physical entities for which the associated value of the
entPhysicalIsFRU object is equal to 'false(2)'.
entity2Compliance
noaccess
Read and write access is not required for agents that
cannot identify serial number information for physical
entities and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for which
the associated value of the entPhysicalIsFRU object is equal
to 'false(2)'.
cannot identify serial number information for physical
entities and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for which
the associated value of the entPhysicalIsFRU object is equal
to 'false(2)'.
entity3Compliance
noaccess
Read and write access is not required for agents that
cannot identify serial number information for physical
entities and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for
which the associated value of the entPhysicalIsFRU object
is equal to 'false(2)'.
cannot identify serial number information for physical
entities and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for
which the associated value of the entPhysicalIsFRU object
is equal to 'false(2)'.
entity4Compliance
noaccess
Read and write access is not required for agents that
cannot identify serial number information for physical
entities and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for
which the associated value of the entPhysicalIsFRU object
is equal to 'false(2)'.
cannot identify serial number information for physical
entities and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for
which the associated value of the entPhysicalIsFRU object
is equal to 'false(2)'.