gntpSyncSource
ENDRUNTECHNOLOGIES-MIB ·
.1.3.6.1.4.1.13827.2.0.8
Object
scalar SNMPv2-TCDisplayString
This is an ASCII string identifying the synchronization source
for this NTP server. It is one of GPS, CPU or NONE. If it is NONE,
then the server is not synchronized, has its Leap Indicator Bits in the Alarm
state and is running at Stratum 16. If it is CPU, then the server is
running on its NTP disciplined CPU clock at Stratum 11.
Check the Stratum, Leap Indicator Bits and Time Figure of Merit for further
information. NTP reply packets from this server will have the reference
identifier field set to gntpSyncSource if it is GPS. Otherwise
it will be set to either 127.127.1.0 (CPU) or 0.0.0.0 (NONE).
Context
- MIB
- ENDRUNTECHNOLOGIES-MIB
- OID
.1.3.6.1.4.1.13827.2.0.8- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- gntp
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ENDRUNTECHNOLOGIES-MIB' -M '/opt/observium/mibs/endrun:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENDRUNTECHNOLOGIES-MIB::gntpSyncSource.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ENDRUNTECHNOLOGIES-MIB' -M '/opt/observium/mibs/endrun:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ENDRUNTECHNOLOGIES-MIB::gntpSyncSource'
Syntax
- Source
- SNMPv2-TCDisplayString
- Base type
OctetString- Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as
US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special
meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the
same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is
illegal. (Note that this also means that a string may
end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255
characters in length.
Values & Constraints
Object Constraints
range: 0-4
Type Constraints
range: 0..255