cfgEmsRetry
ELECTROLINE-DHT-CONFIG-MIB ·
.1.3.6.1.4.1.5802.1.3.1.2.2.1.1.3
Object
This is the number of times that the DHT resends a trap to an EMS that has enabled the trap assurance, if no acknowledge message is received. The default value is zero, meaning that the traps are never resent; a value of -1 means that there is no limit on the number of retries. The same retry count value is used for all EMS entries. The value of this MIB is stored in non-volatile memory.
Context
- MIB
- ELECTROLINE-DHT-CONFIG-MIB
- OID
.1.3.6.1.4.1.5802.1.3.1.2.2.1.1.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- dhtCfgHmsEms
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ELECTROLINE-DHT-CONFIG-MIB' -M '/opt/observium/mibs/electroline:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELECTROLINE-DHT-CONFIG-MIB::cfgEmsRetry.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ELECTROLINE-DHT-CONFIG-MIB' -M '/opt/observium/mibs/electroline:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ELECTROLINE-DHT-CONFIG-MIB::cfgEmsRetry'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647