pmo6006AlmLineTempLowWngPortn

EKINOPS-Pmo6006-MIB · .1.3.6.1.4.1.20044.70.2.3.2.120.1.8

Object

Line Trscv Temp Low Warning :This 
OID indicates that the Trscv temperature 
is lower than the threshold value 
written in the Trscv EEPROM <Help> 
Warning indicating that the Trscv 
temperature is lower than the threshold 
value written in the Trscv EEPROM 
<Condtype> LINE_TEMP_LOW_WNG_1
 <Probcause> temperatureUnacceptable 
(51) <Alarmtype> equipmentAlarm 
(5) <Polarity> (2)

Context

MIB
EKINOPS-Pmo6006-MIB
OID
.1.3.6.1.4.1.20044.70.2.3.2.120.1.8
Type
column
Access
readonly
Status
current
Parent
pmo6006AlmlineNetworkLaneAlarmWarning2Entry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmo6006-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmo6006-MIB::pmo6006AlmLineTempLowWngPortn'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EKINOPS-Pmo6006-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmo6006-MIB::pmo6006AlmLineTempLowWngPortn.<pmo6006AlmlineNetworkLaneAlarmWarning2Index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EKINOPS-Pmo6006-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EKINOPS-Pmo6006-MIB::pmo6006AlmLineTempLowWngPortn'

Syntax

Source
EKINOPS-MIBEkiOnOff
Base type
Enumeration

Values & Constraints

Type Values
1off
2on