pmoailCtrlclientEffPwrOutSettingValue

EKINOPS-PmOail-MIB · .1.3.6.1.4.1.20044.36.6.2.37

Object

scalar r/w Integer32
IL2 Effective Output Power :This 
OID sets the value of the effective 
output power (without noise power) 
of the IL2 Module (active only
 in input power function mode)
 (AV=(Power/0,005) + 32768) (Unit 
= dBm)  <Help>  This control defines 
the IL2 effective output power
 in dBm (valid only in Effective 
Ouput power mode).

Context

MIB
EKINOPS-PmOail-MIB
OID
.1.3.6.1.4.1.20044.36.6.2.37
Type
scalar
Access
readwrite
Status
current
Parent
pmoailCtrlClient

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EKINOPS-PmOail-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-PmOail-MIB::pmoailCtrlclientEffPwrOutSettingValue.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EKINOPS-PmOail-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EKINOPS-PmOail-MIB::pmoailCtrlclientEffPwrOutSettingValue'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-65535