pmoaCtrlclientEffPwrOutSettingValue

EKINOPS-PmOa-MIB · .1.3.6.1.4.1.20044.9.6.2.37

Object

scalar r/w Integer32
Pre-Amp Effective Output Power 
:This OID sets the value of the 
effective output power (without 
noise power) of the Pre-Amp Module 
(active only in input power function 
mode) (AV=(Power/0,005) + 32768) 
(Unit = dBm)  <Help>  This control 
defines the Pre-Amp effective output 
power in dBm (valid only in Effective 
Ouput power mode).

Context

MIB
EKINOPS-PmOa-MIB
OID
.1.3.6.1.4.1.20044.9.6.2.37
Type
scalar
Access
readwrite
Status
current
Parent
pmoaCtrlClient

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EKINOPS-PmOa-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-PmOa-MIB::pmoaCtrlclientEffPwrOutSettingValue.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EKINOPS-PmOa-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EKINOPS-PmOa-MIB::pmoaCtrlclientEffPwrOutSettingValue'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-65535