pmmcAlmLine1VccHighWng

EKINOPS-PmMC-MIB · .1.3.6.1.4.1.20044.21.2.2.1.20.6

Object

TRSCV 1 Power Supply High Warning 
:Warning indicating that the transceiver 
power supply of Line 1 is higher 
than the threshold value written 
in the transceiver EEPROM  <Condtype> 
LINE1_VCC_HIGH_WNG <Probcause>
 powerProblem (36) <Alarmtype>
 equipmentAlarm (5) <Polarity>
 (2)

Context

MIB
EKINOPS-PmMC-MIB
OID
.1.3.6.1.4.1.20044.21.2.2.1.20.6
Type
scalar
Access
readonly
Status
current
Parent
pmmcAlmline1TrscvWarnDdm

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EKINOPS-PmMC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-PmMC-MIB::pmmcAlmLine1VccHighWng.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EKINOPS-PmMC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EKINOPS-PmMC-MIB::pmmcAlmLine1VccHighWng'

Syntax

Source
EKINOPS-MIBEkiOnOff
Base type
Enumeration

Values & Constraints

Type Values
1off
2on