pm801rrAlmLineCdrNotReady

EKINOPS-Pm801RR-MIB · .1.3.6.1.4.1.20044.48.2.3.2.30.9

Object

Line 2 CDR Not Ready :This OID 
indicates the Clock Data Recovery 
unit is not yet initialized   
 <Help>   This alarm indicates
 the Clock Data Recovery unit is 
not yet initialized. <Condtype> 
LINE_CDR_NOT_READY <Probcause>
 receiveFailure (41) <Alarmtype> 
equipmentAlarm (5) <Polarity> (2)

Context

MIB
EKINOPS-Pm801RR-MIB
OID
.1.3.6.1.4.1.20044.48.2.3.2.30.9
Type
scalar
Access
readonly
Status
current
Parent
pm801rrAlmrrLineOtxTlhAlarms3

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EKINOPS-Pm801RR-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm801RR-MIB::pm801rrAlmLineCdrNotReady.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EKINOPS-Pm801RR-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EKINOPS-Pm801RR-MIB::pm801rrAlmLineCdrNotReady'

Syntax

Source
EKINOPS-MIBEkiOnOff
Base type
Enumeration

Values & Constraints

Type Values
1off
2on