pm1005AlmRxPowerHighAlarmPortn
EKINOPS-Pm1005-MIB ·
.1.3.6.1.4.1.20044.26.2.3.2.208.1.17
Object
column
EKINOPS-MIBEkiOnOff
Line Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POWER_HIGH_ALARM_1 <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
Context
- MIB
- EKINOPS-Pm1005-MIB
- OID
.1.3.6.1.4.1.20044.26.2.3.2.208.1.17- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pm1005AlmlineXfp1AlarmEntry
- Table
- pm1005AlmlineXfp1AlarmTable
- Siblings
- 8
Syntax
EKINOPS-MIBEkiOnOff
- Source
- EKINOPS-MIBEkiOnOff
- Base type
Enumeration
Values & Constraints
Type Values
1 | off |
2 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pm1005AlmlineXfp1AlarmIndex Index definition for the pm1005AlmlineXfp1Alarm
table | column | Integer32 | .1.3.6.1.4.1.20044.26.2.3.2.208.1.1 |
| pm1005AlmRxPowerLowAlarmPortn Line Optical Rx Power Low :Alarm
indicating that the XFP received
optical power is lower than the
threshold value written in the
XFP EEPROM <Condtype> RX_POWER_LOW_ALARM_1
<… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.2.208.1.16 |
| pm1005AlmTxPowerLowAlarmPortn Line Optical Tx Power Low :Alarm
indicating that the XFP/OTX transmitter
transmitter output power is lower
than the threshold value written
in the XFP/OTX EEPROM <Condtype>
T… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.2.208.1.2 |
| pm1005AlmTxPowerHighAlarmPortn Line Optical Tx Power High :Alarm
indicating that the XFP/OTX transmitter
transmitter output power is higher
than the threshold value written
in the XFP EEPROM <Condtype> TX_P… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.2.208.1.3 |
| pm1005AlmTxBiasLowAlarmPortn Line Transceiver Bias Low :Alarm
indicating that the XFP/OTX transmitter
laser bias current is lower than
the threshold value written in
the XFP/OTX EEPROM <Condtype>
TX_BIAS… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.2.208.1.4 |
| pm1005AlmTxBiasHighAlarmPortn Line Transceiver Bias High :Alarm
indicating that the XFP/OTX transmitter
laser bias current is higher than
the threshold value written in
the XFP EEPROM <Condtype> TX_BIAS_HI… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.2.208.1.5 |
| pm1005AlmTempLowAlarmPortn Line Transceiver Temp Low :Alarm
indicating that the XFP/OTX temperature
is lower than the threshold value
written in the XFP/OTX EEPROM <Condtype>
TEMP_LOW_ALARM_1 <Probcause… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.2.208.1.8 |
| pm1005AlmTempHighAlarmPortn Line Transceiver Temp High :Alarm
indicating that the XFP/OTX temperature
is higher than the threshold value
written in the XFP EEPROM <Condtype>
TEMP_HIGH_ALARM_1 <Probcause>… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.2.208.1.9 |