pm1005AlmLineLocalOosPortn
EKINOPS-Pm1005-MIB ·
.1.3.6.1.4.1.20044.26.2.3.3.7.1.7
Object
column
EKINOPS-MIBEkiOnOff
Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service <Condtype> LINE_LOCAL_OOS <Probcause> informationalStatus(1000) <Alarmtype> other (1) <Polarity> (2)
Context
- MIB
- EKINOPS-Pm1005-MIB
- OID
.1.3.6.1.4.1.20044.26.2.3.3.7.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pm1005AlmsynthAlmLineEntry
- Table
- pm1005AlmsynthAlmLineTable
- Siblings
- 10
Syntax
EKINOPS-MIBEkiOnOff
- Source
- EKINOPS-MIBEkiOnOff
- Base type
Enumeration
Values & Constraints
Type Values
1 | off |
2 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pm1005AlmsynthAlmLineIndex Index definition for the pm1005AlmsynthAlmLine
table | column | Integer32 | .1.3.6.1.4.1.20044.26.2.3.3.7.1.1 |
| pm1005AlmLineDdmWarningPortn Warning On Line Optical Module
DDM :This OID indicates a warning
is present coming out of Line optical
interface DDM <Help> This alarm
indicates if a DDM Warning has
been d… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.3.7.1.10 |
| pm1005AlmLineDdmAlmPortn Alarm On Line Optical Module DDM
:This OID indicates an alarm is
present coming out of Line optical
interface DDM <Help> This alarm
indicates if a DDM Alarm has been
detect… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.3.7.1.11 |
| pm1005AlmLineFailPortn Line Port Failure :This OID indicates
a failure on the line port <Condtype>
LINE_FAIL <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2) | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.3.7.1.13 |
| pm1005AlmLineActivePortn Line Active :This bit indicates
the line #n is active on receive
side <Help> This status indicates
whether the line is active or standby.
<Condtype> LINE_ACTIVE <Probcause> … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.3.7.1.17 |
| pm1005AlmXfpAbsentPortn Line Optical Module Absent :This
OID indicates that the line optical
interface (XFP or OTX) is not plugged
in. <Help> This alarm indicates
if the line transceiver is present… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.3.7.1.2 |
| pm1005AlmXfpInitNotComplPortn Line Optical Module Ready :This
OID indicates that the optical
interface (XFP or OTX) is not
operational. <Help> This status
indicates if the line transceiver
has been corr… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.3.7.1.3 |
| pm1005AlmLineHwFailPortn Line Port HW Failure :This OID
indicates a failure on line port,
most probably caused by a HW issue
<Condtype> LINE_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.3.7.1.5 |
| pm1005AlmXfpTxOffPortn Line Optical Module Laser Shutdown
:This OID indicates the line optical
output power is on <Help> This
status indicates if the line transceiver
laser is ON or OFF <Condtype>… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.3.7.1.6 |
| pm1005AlmUpRdiInsPortn MS-RDI/L-RDI Inserted On Line
:This OID indicates an upstream
MS-RDI/L-RDI has been inserted
in the outgoing 10 Gb/s SDH/SONET
signal. <Help> This status indicates
if a MS… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.26.2.3.3.7.1.9 |