pm10001otu4AlmLineActivePortn
EKINOPS-Pm10001otu4-MIB ·
.1.3.6.1.4.1.20044.82.2.3.3.24.1.17
Object
column
EKINOPS-MIBEkiOnOff
Line Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIVE <Probcause> informationalStatus(1000) <Alarmtype> other (1) <Polarity> (2)
Context
- MIB
- EKINOPS-Pm10001otu4-MIB
- OID
.1.3.6.1.4.1.20044.82.2.3.3.24.1.17- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pm10001otu4AlmsynthAlmLineEntry
- Table
- pm10001otu4AlmsynthAlmLineTable
- Siblings
- 10
Syntax
EKINOPS-MIBEkiOnOff
- Source
- EKINOPS-MIBEkiOnOff
- Base type
Enumeration
Values & Constraints
Type Values
1 | off |
2 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pm10001otu4AlmsynthAlmLineIndex Index definition for the pm10001otu4AlmsynthAlmLine
table | column | Integer32 | .1.3.6.1.4.1.20044.82.2.3.3.24.1.1 |
| pm10001otu4AlmLineDdmWarningPortn Warning On Line Optical Module
DDM :This OID indicates a warning
is present coming out of Line transceiver
DDM <Help> This alarm indicates
if a DDM Warning has been detected
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.3.3.24.1.10 |
| pm10001otu4AlmLineDdmAlmPortn Alarm On Line Optical Module DDM
:This OID indicates an alarm is
present coming out of Line transceiver
DDM <Help> This alarm indicates
if a DDM Alarm has been detected
on th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.3.3.24.1.11 |
| pm10001otu4AlmLineFailPortn Line Port Failure :This OID indicates
a failure on the line port <Help>
This alarm indicates a failure
on the line port <Condtype> LINE_FAIL
<Probcause> equipmentMalfunction
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.3.3.24.1.13 |
| pm10001otu4AlmXfpAbsentPortn Line Optical Module Absent :This
OID indicates that the line optical
interface is not present. <Help>
This alarm indicates if the line
transceiver is not plugged <Condtype>
X… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.3.3.24.1.2 |
| pm10001otu4AlmXfpInitNotComplPortn Line Optical Module Ready :This
OID indicates that the optical
interface is not operational.
<Help> This status indicates if
the line transceiver has been correctly
initializ… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.3.3.24.1.3 |
| pm10001otu4AlmLineHwFailPortn Line Port HW Failure :This OID
indicates a failure on line port,
most probably caused by a HW issue
<Help> This alarm indicates a failure
on line port, most probably caused
b… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.3.3.24.1.5 |
| pm10001otu4AlmXfpTxOffPortn Line Trscv Laser Shutdown :This
OID indicates the Line transceiver
laser is shutdown <Help> This status
indicates if the Line transceiver
laser is shutdown <Condtype> XFP_TX_O… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.3.3.24.1.6 |
| pm10001otu4AlmLineLocalOosPortn Line Port In Service :This OID
indicates that the Line port is
In Service (1) of Out or Service
(2) <Help> This status indicates
if the line port is in service
<Condtype> LIN… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.3.3.24.1.7 |
| pm10001otu4AlmUpRdiInsPortn MS-RDI/L-RDI Inserted On Line
:This OID indicates an upstream
MS-RDI/L-RDI has been inserted
in the outgoing 10 Gb/s SDH/SONET
signal. <Help> This status indicates
if a MS-RD… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.3.3.24.1.9 |