pm10001otu4AlmClientLaserTempLowWarningPortn
EKINOPS-Pm10001otu4-MIB ·
.1.3.6.1.4.1.20044.82.2.2.1.56.1.7
Object
column
EKINOPS-MIBEkiOnOff
Client Trscv Laser Temp Low Warning :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Condtype> CLIENT_LASER_TEMP_LOW_WARNING <Probcause> temperatureUnacceptable (51) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
Context
- MIB
- EKINOPS-Pm10001otu4-MIB
- OID
.1.3.6.1.4.1.20044.82.2.2.1.56.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pm10001otu4AlmclientNetworkLaneAlarmWarningEntry
- Table
- pm10001otu4AlmclientNetworkLaneAlarmWarningTable
- Siblings
- 16
Syntax
EKINOPS-MIBEkiOnOff
- Source
- EKINOPS-MIBEkiOnOff
- Base type
Enumeration
Values & Constraints
Type Values
1 | off |
2 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pm10001otu4AlmclientNetworkLaneAlarmWarningIndex Index definition for the pm10001otu4AlmclientNetworkLaneAlarmWarning
table | column | Integer32 | .1.3.6.1.4.1.20044.82.2.2.1.56.1.1 |
| pm10001otu4AlmClientTxPowerLowAlarmPortn Client Trscv Tx Power Low Alarm
:This OID indicates that the Trscv
output power is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that the… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.10 |
| pm10001otu4AlmClientTxPowerLowWarningPortn Client Trscv Tx Power Low Warning
:This OID indicates that the Trscv
output power is lower than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.11 |
| pm10001otu4AlmClientTxPowerHighWarningPortn Client Trscv Tx Power High Warning
:This OID indicates that the Trscv
output power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.12 |
| pm10001otu4AlmClientTxPowerHighAlarmPortn Client Trscv Tx Power High Alarm
:This OID indicates that the Trscv
output power is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that t… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.13 |
| pm10001otu4AlmClientBiasLowAlarmPortn Client Trscv Bias Low Alarm :This
OID indicates that the Trscv laser
bias current is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that t… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.14 |
| pm10001otu4AlmClientBiasLowWarningPortn Client Trscv Bias Low Warning
:This OID indicates that the Trscv
laser bias current is lower than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.15 |
| pm10001otu4AlmClientBiasHighWarningPortn Client Trscv Bias High Warning
:This OID indicates that the Trscv
laser bias current is higher than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.16 |
| pm10001otu4AlmClientBiasHighAlarmPortn Client Trscv Bias High Alarm :This
OID indicates that the Trscv laser
bias current is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.17 |
| pm10001otu4AlmClientRxPowerLowAlarmPortn Client Trscv Rx Power Low Alarm
:This OID indicates that the Trscv
input power is lower than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.2 |
| pm10001otu4AlmClientRxPowerLowWarningPortn Client Trscv Rx Power Low Warning
:This OID indicates that the Trscv
input power is lower than the threshold
value written in the Trscv EEPROM
<Help> Warning indicating that
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.3 |
| pm10001otu4AlmClientRxPowerHighWarningPortn Client Trscv Rx Power High Warning
:This OID indicates that the Trscv
input power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
tha… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.4 |
| pm10001otu4AlmClientRxPowerHighAlarmPortn Client Trscv Rx Power High Alarm
:This OID indicates that the Trscv
input power is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.5 |
| pm10001otu4AlmLaserTempLowAlarmPortn Client Trscv Laser Temp Low Alarm
:This OID indicates that the Trscv
Laser Temperature is lower than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating t… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.6 |
| pm10001otu4AlmClientLaserTempHighWarningPortn Client Trscv Laser Temp High Warning
:This OID indicates that the Trscv
Laser Temperature is higher than
the threshold value written in
the Trscv EEPROM <Help> Warning
indica… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.8 |
| pm10001otu4AlmClientLaserTempHighAlarmPortn Client Trscv Laser Temp High Alarm
:This OID indicates that the Trscv
Laser Temperature is higher than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.82.2.2.1.56.1.9 |