pm1001pcAlmLineTecFault

EKINOPS-PM1001PC-MIB · .1.3.6.1.4.1.20044.12.2.3.3.211.15

Object

Line Optical Tx Temp Regul. Failed 
:This OID indicates a failure on 
the TEC module  <Help>  This alarm 
indicates if the TEC of the line 
transceiver is in fail condition 
<Condtype> LINE_TEC_FAULT <Probcause> 
transmitterFailure (56) <Alarmtype> 
equipmentAlarm (5) <Polarity> (2)

Context

MIB
EKINOPS-PM1001PC-MIB
OID
.1.3.6.1.4.1.20044.12.2.3.3.211.15
Type
scalar
Access
readonly
Status
current
Parent
pm1001pcAlmlineXfpAlarms2

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EKINOPS-PM1001PC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-PM1001PC-MIB::pm1001pcAlmLineTecFault.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EKINOPS-PM1001PC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EKINOPS-PM1001PC-MIB::pm1001pcAlmLineTecFault'

Syntax

Source
EKINOPS-MIBEkiOnOff
Base type
Enumeration

Values & Constraints

Type Values
1off
2on