rndMonitoringLogfile
EDGECORE-rndApplications ·
.1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.10
Object
The entire path of the file in which the results of the monitoring of this object instance should be recorded.
Context
- MIB
- EDGECORE-rndApplications
- OID
.1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.10- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- rndMonitoringEntry
- Table
- rndMonitoringTable
- Siblings
- 11
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rndMonitoredElement A label assigned by the network manager to a monitored element to
which this monitored object instance belongs. This label must have
been previously entered in an instance of rndM… | column | OctetString | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.1 |
| rndMonitoringEntryStatus It is used to manage the monitored object instances table and
indicates the current monitoring status of an object instance. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.11 |
| rndMonitoredIntegerInstance | column | Integer32 | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.12 |
| rndMonitoredObjectInstanceLabel The label assigned by the network manager to the monitored object instance | column | OctetString | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.2 |
| rndMonitoredObjectName The symbolic object type name of the object to which the monitored object
instance belongs (as it appears the MIB module definition). In case of
ambiguity the <MIB module name> : … | column | OctetString | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.3 |
| rndMonitoredObjectIdentifier The object identifier of the object to which the monitored object
instance belongs.
An instance of rndMonitoredObjectIdentifier need not be assigned any value, if
the correspondin… | column | ObjectIdentifier | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.4 |
| rndMonitoredObjectInstance The instance identifier (key) of the monitored object instance. | column | ObjectIdentifier | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.5 |
| rndMonitoredObjectSyntax The syntax of the monitored object instance (i.e., the syntax of the object
type of the object to which the monitored instance belongs).
Need not be assigned any value if the corr… | column | Enumeration | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.6 |
| rndMonitoringInterval The period of time between two consecutive retrievals of the monitored
object instance's value. | column | Integer32 | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.7 |
| rndAlarmMaxTreshold The value of the monitored object instance, the exceeding of which
will cause the generation of an alarm to the high-level management
station. | column | Integer32 | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.8 |
| rndAlarmMinTreshold If the value of the monitored object instance falls below the value
assigned to rndAlarmMinTreshold, an alarm to the high-level management
station will be issued. | column | Integer32 | .1.3.6.1.4.1.259.10.1.14.89.35.2.4.1.9 |