portComboForcedMode
ECS4620-MIB ·
.1.3.6.1.4.1.259.10.1.41.1.2.1.1.12
Object
column
r/w
Enumeration
This determines the running mode of a combo port. For a non-combo port, this variable has a value of none(1), and setting this variable to none(1) has no effect. For a combo port, this has its own valid values not equal to none(1), and setting this variable to none(1) is not allowed. copperForced(2) is set if user want to force this combo port running in copper mode. copperPreferredAuto(3) is obsoleted, and user shall not set this state. sfpForced(4) is set if user want to force this combo port running in fiber mode. sfpPreferredAuto(5) is set if user want to change copper or fiber mode automatically by SFP transceiver present state. If SFP transceiver is present, this combo port will run in fiber mode, and if SFP transceiver is not present, this combo port will run in copper mode.
Context
- MIB
- ECS4620-MIB
- OID
.1.3.6.1.4.1.259.10.1.41.1.2.1.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- portEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | none |
2 | copperForced |
3 | copperPreferredAuto |
4 | sfpForced |
5 | sfpPreferredAuto |