matchingTimeout
E5-121-MIB ·
.1.3.6.1.4.1.6321.1.2.3.4.16.2.4.1.4
Object
scalar
r/w
Integer32
If a pattern string is fully matched, and there are other pattern strings partially matched, the pattern string will be sent out if the timeout happens, 1 ~ 20 seconds.
Context
- MIB
- E5-121-MIB
- OID
.1.3.6.1.4.1.6321.1.2.3.4.16.2.4.1.4- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- timeoutSetup
- Siblings
- 3
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-20
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| initialTimeout First digit must be dialed before this timeout, 1 ~ 20 seconds. | scalar | Integer32 | .1.3.6.1.4.1.6321.1.2.3.4.16.2.4.1.1 |
| interDigitTimeout If no pattern string is fully matched, the inter-digit timeout will
trigger device to send out current dialed digits, 1 ~ 20 seconds. | scalar | Integer32 | .1.3.6.1.4.1.6321.1.2.3.4.16.2.4.1.2 |
| digitPauseTimeout If a pattern string is end with the T pattern, the pattern string
will not be matched until the timeout happens, 1 ~ 20 seconds. | scalar | Integer32 | .1.3.6.1.4.1.6321.1.2.3.4.16.2.4.1.3 |