iesSlotModuleAlarmStatus

E5-121-IESCOMMON-MIB · .1.3.6.1.4.1.6321.1.2.3.4.98.1.3.1.8

Object

column Integer32
This variable indicates the alarm status of the module.
It is a bit map represented as a sum, therefore, it can represent
multiple defects simultaneously. The moduleNoDefect should be set
if and only if no other flag is set.
              
The various bit positions are:
1   moduleNoDefect
2   moduleOverHeat
3	 moduleFanRpmLow
4	 moduleVoltageLow
5   moduleThermalSensorFailure
6   modulePullOut
7   powerDC48VAFailure
8   powerDC48VBFailure
9   extAlarmInputTrigger
10   moduleDown
11 	 mscSwitchOverOK
12	 networkTopologyChange

Context

MIB
E5-121-IESCOMMON-MIB
OID
.1.3.6.1.4.1.6321.1.2.3.4.98.1.3.1.8
Type
column
Access
readonly
Status
current
Parent
iesSlotEntry
Table
iesSlotTable
Siblings
7

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-255

Related Objects

Sibling Objects