The managed object is for system maintenance. When the EMS wants to trigger the system maitenance operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: config save BIT 2: reset BIT 3: local loopback test BIT 4: remote loopback test BIT 5: clear system alarms BIT 6: F4 loopback test BIT 7: F5 loopback test BIT 8: DSL Line Diagnostic
Context
- MIB
- E5-121-IESCOMMON-MIB
- OID
.1.3.6.1.4.1.6321.1.2.3.4.98.3.2.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- iesSysMaintenance
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.