iesMaintenanceOps

E5-120-IESCOMMON-MIB · .1.3.6.1.4.1.6321.1.2.3.3.98.3.2.1

Object

scalar r/w Integer32
The managed object is for system maintenance. When the EMS
wants to trigger the system maitenance operation, the EMS
shall send SNMP-SET message to set the corresponding bit value
to be 1. The various bit positions are:
BIT 1: config save
BIT 2: reset
BIT 3: local loopback test
BIT 4: remote loopback test
BIT 5: clear system alarms
BIT 6: F4 loopback test
BIT 7: F5 loopback test
BIT 8: DSL Line Diagnostic

Context

MIB
E5-120-IESCOMMON-MIB
OID
.1.3.6.1.4.1.6321.1.2.3.3.98.3.2.1
Type
scalar
Access
readwrite
Status
current
Parent
iesSysMaintenance

Syntax

Integer32

Values & Constraints

No enumerated values or constraints recorded.