docsPnmCmtsUsOfdmaAQProbeTimeout
DOCS-PNM-MIB ·
.1.3.6.1.4.1.4491.2.1.27.1.3.3.1.5
Object
column
r/w
seconds Unsigned32
This attribute provides a timeout for the measurement if the CMTS is
unable to perform the measurement for some reason. A value of zero for
the Timeout attribute means that the measurement continues to be active
until the measurement is completed or until the Enable attribute is cleared.
This object cannot be changed while a capture is in progress. It will
return a value of 'inconsistentValue' if set while the value of
'docsPnmCmtsUsOfdmaAQProbeMeasStatus' is set to a value of 'busy'.
Context
- MIB
- DOCS-PNM-MIB
- OID
.1.3.6.1.4.1.4491.2.1.27.1.3.3.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- docsPnmCmtsUsOfdmaAQProbeEntry
Syntax
seconds Unsigned32
Values & Constraints
Object Constraints
range: 0-65535