docsPnmCmtsDsOfdmSymTrigGroupId
DOCS-PNM-MIB ·
.1.3.6.1.4.1.4491.2.1.27.1.3.1.1.2
Object
column
r/w
Unsigned32
This attribute is used by the CMTS to be inserted in the PLC Trigger
Message Block to identify a CM or a group of CMs expected to perform
Symbol Capture measurements for the designated symbol.
This value can only be changed while a test is not in progress. An attempt
to set this value while the value of 'docsPnmCmtsDsOfdmSymMeasStatus' is
'busy' will return 'inconsistentValue'.
Context
- MIB
- DOCS-PNM-MIB
- OID
.1.3.6.1.4.1.4491.2.1.27.1.3.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- docsPnmCmtsDsOfdmSymCapEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-65535