swRadiusAcctUpdateInterval

DLINK-AUTH-MIB · .1.3.6.1.4.1.171.12.3.4.1

Object

scalar r/w Unsigned32
Time interval after which this Radius record
should be updated and sent to an
accounting server.

Context

MIB
DLINK-AUTH-MIB
OID
.1.3.6.1.4.1.171.12.3.4.1
Type
scalar
Access
readwrite
Status
current
Parent
swRadiusAccountingCtrl

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'DLINK-AUTH-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DLINK-AUTH-MIB::swRadiusAcctUpdateInterval.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'DLINK-AUTH-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'DLINK-AUTH-MIB::swRadiusAcctUpdateInterval'

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 1-65535