sysLBDInterval

DGS-1210-28XME-BX · .1.3.6.1.4.1.171.10.76.43.1.17.3

Object

scalar r/w Integer32
Set a Loop detection Interval between 1 and 32767 seconds.
The default is 2 seconds.
This time interval to be used at counting time seconds to
resend the CTP packet automatically.

Context

MIB
DGS-1210-28XME-BX
OID
.1.3.6.1.4.1.171.10.76.43.1.17.3
Type
scalar
Access
readwrite
Status
current
Default
2
Parent
companyLBD

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'DGS-1210-28XME-BX' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-1210-28XME-BX::sysLBDInterval.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'DGS-1210-28XME-BX' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'DGS-1210-28XME-BX::sysLBDInterval'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-32767