vctAction
DCN-MIB ·
.1.3.6.1.4.1.6339.100.3.2.1.18
Object
column
r/w
Integer32
This object indicates the VCT action of the port,only the value 1 is permitted when SET this entry though you can GET 1(processing) and 0(succeed); The specified port will be shutdown when one sets 1 to this entry,and then it will return to no shutdown after operate the virtual-cable-test. You can get the status of VCT from the entry vctLastStatus.
Context
- MIB
- DCN-MIB
- OID
.1.3.6.1.4.1.6339.100.3.2.1.18- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- priPortEntry
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.