nvramEnvAlert
DATA-DOMAIN-MIB ·
.1.3.6.1.4.1.19746.2.0.6505
Object
notification
Description:
The temperature sensor on the NVRAM card or the remote battery detected a temperature
that is higher than the warning threshold. If there are other environmental alerts,
this may indicate a cooling problem where the system is installed.
If there are no other environmental alerts, this may indicate a problem with this component.
When the temperature is reduced, this alert will clear.
Action:
Check cooling and airflow around the system unit. Remove any blockage, or ensure
the environmental systems are operating correctly, and the environment is at a normal
temperature. If there is no problem in the environment, or if only the NVRAM or
remote battery are reporting this problem, contact your contracted support provider or visit us online at https://support.emc.com.
Context
- MIB
- DATA-DOMAIN-MIB
- OID
.1.3.6.1.4.1.19746.2.0.6505- Type
- notification
- Status
- current
- Parent
- dataDomainMibTraps
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workNotifications are emitted by an agent; they cannot be read with snmpget or walked.
Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'DATA-DOMAIN-MIB' -M '/opt/observium/mibs/datadomain:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'DATA-DOMAIN-MIB::nvramEnvAlert'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'DATA-DOMAIN-MIB' -M '/opt/observium/mibs/datadomain:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'DATA-DOMAIN-MIB::nvramEnvAlert'
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Conformance
Member of