ctWanHDSLAlarmsES

CTRON-WAN-MIB · .1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.3

Object

column mandatory Integer32
A two bytes value for the Errored Second indication of the HDSL 
line unit, including local, remote line units and the doublers.
each bit in the two bytes value has the following meaning if set: 
              
Bit 0 : Errored Second on LOOP 1 of local line unit.
    1 : Errored Second on LOOP 2 of local line unit. 
    2 : Errored Second on LOOP 1 of remote line unit.
    3 : Errored Second on LOOP 2 of remote line unit.  
    4 : Errored Second on LOOP 1 of local line unit's network side.
    5 : Errored Second on LOOP 2 of local line unit's network side.
    6 : Errored Second on LOOP 1 of local line unit's customer side.
    7 : Errored Second on LOOP 2 of local line unit's customer side.

Context

MIB
CTRON-WAN-MIB
OID
.1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.3
Type
column
Access
readonly
Status
mandatory
Parent
ctWanHDSLAlarmsEntry

Syntax

Integer32

Values & Constraints

No enumerated values or constraints recorded.