bdgPortRuntPackets
CTRON-BDG-MIB ·
.1.3.6.1.4.1.52.1.3.1.2.25
Object
The number of packets received at the indicated bdgPort that were less than the IEEE 802.3 minimum Ethernet frame size of 64 bytes.
Context
- MIB
- CTRON-BDG-MIB
- OID
.1.3.6.1.4.1.52.1.3.1.2.25- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- bdgPort
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CTRON-BDG-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-BDG-MIB::bdgPortRuntPackets.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CTRON-BDG-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CTRON-BDG-MIB::bdgPortRuntPackets'
Syntax
- Source
- RFC1155-SMICounter
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295